RBC Resistance Bridge Calibrators

- Temperature Coefficient: < ±0.3 ppm/ °C.

- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house

- Calibrate ac and dc thermometry bridges

- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)

- Patented design licensed from IRL

- Windows application for full analysis and reporting

Brief specifications


More details

Operating principles The problem: Temperature measurement is one of the most demanding applications of resistance measurement. It requires the measurement of resistance ratios to accuracies of 0.1ppm or better. While dc resistance standards are sometimes available at this level, ac resistance standards are generally not. So how can we show our bridges are accurate at this level, and that our resistance and temperature measurements are traceable? The linearity check One simple method for checking a resistance bridge is to measure a pair of resistors separately, and then measure the two in series. Ideally the series measurement should equal the sum of the two individual measurements. If not, then the measurements give us a bit of information about the errors in the bridge readings. Note that we do not need to know the values of the resistors to make this test work. The complement check Another check is to measure the ratio of two resistances, say R1/R2, then swap the resistors and measure the reciprocal ratio (or complement), R2/R1. Ideally the product of the two measurements should equal 1.0 exactly, if not, the measurements give us more information on the bridge errors. Once again, we do not need to know the values of the resistors to make this test work. The combinatorial method The RBC exploits the same principles as the linearity and complement check. It uses a network of four stable four terminal resistors that can be connected in 35 different series and parallel combinations. By measuring each RBC combination in the two different ways (as with the complement check) up to 70 different measurements can be made. Since the RBC has just four unknown resistance values, we have up to 66 independent measurements containing information about the errors in the bridge readings. The combinatorial calibration method is particularly powerful because it is not necessary to know the actual values of the four resistors, or their frequency dependence. This means we can calibrate any ac or dc bridge to any accuracy, so long as the various resistance combinations are accurate. The patented RBC Calibrators are a result of research carried out by Rod White at the Measurement Standards Laboratory of New Zealand, which operates within Industrial Research Ltd (IRL). Isothermal Technology Ltd has an exclusive licence from IRL to develop, sell and produce the RBC. Introducing the RBC


ВимірюванняГенерація (Імітація)


RBC Resistance Bridge Calibrators

- Temperature Coefficient: < ±0.3 ppm/ °C.

- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house

- Calibrate ac and dc thermometry bridges

- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)

- Patented design licensed from IRL

- Windows application for full analysis and reporting

Featured Products

4010 advanced multiproduct calibrator
4010 advanced multiproduct calibrator
The 4000 Series is aimed at laboratories, manufacturers and design facilities requiring a wide range of outputs with accuracies up to 8ppm. The 4000 Series builds on the trusted reliability of the 3000A series, offering an updated user inte...
Код: 4010
ADT783 Pressure Controller
ADT783 Pressure Controller
These modular pressure controllers combine cutting-edge control/measurement technology, modular design, and user-friendly features. The Additel 783 controller series is optimized for high speed to pressure without compromising accuracy and ...
Код: ADT783
AC/DC shunts precision references and standards
AC/DC shunts precision references and standards
Transmille offer a set of current shunts enabling measurement of current from 1mA through to 100A. Each shunt develops 0.7V at nominal full scale, enabling a wide range of multimeters to be used without loss of resolution due to changing ra...
Код: AC/DC
Additel 681A Digital Pressure Gauge
Additel 681A Digital Pressure Gauge
Additel’s 681A Series Digital Pressure Gauges are designed to be your favorite tool for a wide range of pressure measurement and calibration applications. With features such as datalogging and Bluetooth technology included, you will find th...
Код: ADT681A
9340-4T Series of precision RTD Simulators and DC Resistance Standards
9340-4T Series of precision RTD Simulators and DC Resistance Standards
Guildline Instruments 9340-4T Series of precision RTD Simulators and DC Resistance Standards are a complete family of easy to use low to ultra-low, 4 Wire resistance standards offering the best combination of accuracy and resistance range t...
Код: 9340-4T
Additel 760 Automatic Handheld Pressure Calibrators
Additel 760 Automatic Handheld Pressure Calibrators
A portable automated pressure calibrator in the palm of your hand—this could be our most exciting product yet! The Additel 760 series Automatic Handheld Pressure Calibrator takes portable pressure calibration to new levels. Weighing less th...
Код: ADT760
MODEL 9200&9210DC MULTI-VALUE RESISTANCE STANDARDS & CURRENT SHUNTS
MODEL 9200&9210DC MULTI-VALUE RESISTANCE STANDARDS & CURRENT SHUNTS
THE 9200 AND 9210 PROVIDE DUAL CAPABILITIES AS A VERSATILE HIGH POWER MULTIPLE VALUE RESISTANCE STANDARD OR AS A PRECISION DC CURRENT SHUNT PRODUCT FEATURES Accuracy ± 0.01% (100 ppm) Resistance Values from 0.01 to 10,000 Ω (Model 9200) Res...
Код: MODEL
ADTS552F Air data test system
ADTS552F Air data test system
The ADTS552F air data test set is a portable two-channel flightline pitot static tester with large pitot static volume capability for use on a wide range of aircraft, from light aircraft to wide body passenger and freight aircraft. It provi...
Код: ADTS552F
PROSITE on-site calibration database
On-site calibration is becoming an ever more important part of many calibration laboratories workloads. So why perform this calibration any differently from in the laboratory? ProSite software allows the user to take their instrument databa...
Код: PROSITE
Standard Thermocouple Model 1600 NCJ
Standard Thermocouple Model 1600 NCJ
The Isothermal range of Thermocouple Standards are the result of many years development. The type R and S standards will cover the range from 0°C to 1600°C. The measuring assembly comprises a 7mm x 300mm or 600mm gas tight 99.7% recrystalli...
4.5000/5 2text_more_review
Код:
Oberon R Model 426
Oberon R Model 426
The Oberon R uses a Sodium heat Pipe to ensure an exceptionally low temperature gradient along the furnace core. It is ideal for the realization of Aluminium, Silver or Copper ITS-90 Fixed Points. It may be used as a blackbody source over t...
Код: 427
DPI611 Handheld Pressure Calibrator
DPI611 Handheld Pressure Calibrator
Druck DPI611 is a portable pressure calibrator that provides accuracy, reliability and ease of use. It combines a compact design with high performance, making it the ideal choice for calibration professionals. This calibrator is capable ...
Код: DPI 611
XGA301 Industrial Gas Analyzer
XGA301 Industrial Gas Analyzer
The XGA301 Industrial gas analyzer from Michell Instruments provides a convenient platform to measure oxygen, dew point, CO2 and CH4. The analyzer can be supplied in one of two bench-mounted chassis and with up to three sensors fitted. Sta...
Код: XGA301
Interchangeable Humidity and Temperature Sensor - Michell HygroSmart I7000XP Series
The HygroSmart I7000XP sensor is designed to accurately and reliably measure relative humidity and temperature in a wide spectrum of industrial and heavy industrial applications. The sensor uses the latest HygroSmart 3 technology, providing...
Код: I7000XP
Cyclops Model 878
Cyclops Model 878
The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for use as a radiation source for infrared thermometers. The inner sphere has a nominal diamete...
4.0000/5 2text_more_review
Код: 879
HPPP480 Calibration system for gas meters with natural gas
HPPP480 Calibration system for gas meters with natural gas The calibration system serves as a standard for the calibration of gas meters of natural gas. The supply of natural gas occurs directly from a pipeline. The gas used for calibrat...
Код: HPPP480
Michell Easidew Sampler
Michell Easidew Sampler
A low-cost, self-contained sampling system, with filtration and flow control, for measurement of either pressure or atmospheric dew points...
Код: Easidew Sampler
DPS5000 Series  Digital Pressure Sensors
DPS5000 Series  Digital Pressure Sensors
The DPS5000 I2C from Druck, part of the UNIK5000 family, offers integrated digital electronics to enhance the performance level of the UNIK5000 Pressure Sensing Platform to levels unmatched by traditional analog sensors. It features an I2C ...
Код: DPS5000
Meteorology RH and T Probes - Rotronic MP100A/MP400A
The MP100A is a combined humidity and temperature probe designed primarily for meteorological and general outdoor applications. Operation from DC voltage and low power consumption make the MP101A particularly suitable for operation at remot...
Код: MP100A/MP400A
Compact Sampling System - Michell ES20
Compact Sampling System - Michell ES20
The ES20 Compact Sampling System is designed to reliably and accurately measure dew point or moisture content in a wide variety of industrial gas applications up to 20 barg. This sampling system is an economical and high-quality solution wi...
Код: ES20