Categories
-
Pressure
-
Temperature
-
Humidity
-
Electrical signals
- Calibrator of electrical signals
- Reference multimeters
- Voltage, resistance, frequency standards
- Precision bridges
- Teraohmmeter
- Reference electricity meters
- Installations for verification of electricity meters
- Power analyzers
- Voltage dividers
- Current shunts
- Precision current transformers
- Systems for measuring current
- Precision measuring systems
- Test Equipment
- Liquid and air baths for resistance measures
- Standards of conductivity (salinity)
- Software
- Accessories
- Multifunction calibrators
-
Flow measurement
-
Chemical composition
-
Complex solutions
-
Services
Temperature Controlled Fixed Resistors
- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C
- Model 456. By temperature controlling an otherwise very stable resistor a performance close to the very best available World-wide can be achieved at a surprisingly low price.
- Nominal Temperature Coefficient of Resistance: +0.02ppm/°C (with temperature control on) 18 to 25°C
- Power Rating: 0.5 Watt at +25°C
- Standard models: 10, 25, 100, 1000 and 10,000Ω
- Current Noise: <0.010µV (RMS) / Volt of Applied Voltage
- Thermal EMF: 0.1µV/°C Max; 0.05µV/°C Typical
- The most precise and stable resistors available
- Impervious to harmful environments - oil filled
- Temperature coefficient of resistance 2ppm/°C 0.5ppm to special order
- Eventually all resistance thermometry refers back to one or more fixed resistors. These are a key element in any laboratory which measures temperature.
RBC Resistance Bridge Calibrators
- Temperature Coefficient: < ±0.3 ppm/ °C.
- The problem: Temperature measurement is one of the most demanding applications of resistance measurement. Calibrate thermometry bridges quickly, simply and in-house
- Calibrate ac and dc thermometry bridges
- High accuracy - better than 0.01 ppm at 100 Ohms (RBC100A)
- Patented design licensed from IRL
- Windows application for full analysis and reporting
- -270°C to 1820°C
- The millisKanner channel expander has eight input channels, and each can be configured individually for SPRT, PRT, Thermistor or Thermocouple input.
- Expands milliK to a maximum of 33 Channels
- Supports SPRTs, PRTs, Thermistors and Thermocouples
- Universal Inputs for Flexibility
microK Precision Thermometry Bridge
- -200°C to 1800°C
- The microK 70 and 125 models are designed for the Primary Temperature Laboratories whilst the microK 250 and 500 models were designed for the Secondary Laboratory as well as a wide range of high accuracy industrial and scientific calibration applications.
- Ratio Accuracy to <0.02ppm (20ppb) with Zero Drift
- SPRTs, PRTs, RTDs, Thermistors and Thermocouples
- Reliable 21st Century 100% Solid State Design
- -200°C to 1800°C
- Best performance, documented, guaranteed with an unmatched satisfaction promise.
- Ratio Accuracy to <0.02ppm (20ppb) with Zero Drift
- SPRTs, PRTs, RTDs, Thermistors and Thermocouples
- Reliable 21st Century 100% Solid State Design
- -200°C to 1800°C
- The microsKanner can be used with any member of the microK family to add further channels, up to a maximum of 90 expansion channels.
- Expandable to 90 channels
- Supports PRTs, thermocouples & thermistors
- Plug-and-play operation

-350x280.jpg)
-350x280.jpg)





-350x280.jpeg)























-327x226.jpeg)
-327x226.jpeg)

-327x226.jpeg)
-327x226.jpeg)