Каталог
Назад

Tek Know Ukraine

Solution for metrology

With us expertly :)

TTI-22

- -250°C to 962°C

- Quite simply the Isotech TTI-22 High Accuracy Thermometer sets new standards in the price to performance ratio for industrial and secondary resistance thermometry.

- Accuracy of 0.001°C and a resolution of 0.0001°C (0.00004 Ohms)

- A reference thermometer for your PRT or SPRT Standards

- For use in the lab or to achieve the highest accuracy in the field

Brief specifications


More details

Quite simply the Isotech TTI-22 High Accuracy Thermometer sets new standards in the price to performance ratio for industrial and secondary resistance thermometry. If you need high accuracy at an affordable price you have to look at the TTI-22. The TTI-22 has an accuracy of 0.001°C and a resolution of 0.0001°C (0.00004 Ohms). It has two input channels, is lightweight (1.8kg) and will operate for more than 10 hours from two small AA cells. It has both RS232 and Ethernet ports. Simple to use, supporting both Industrial 100 Ohm probe and SPRTs to ITS-90, 25.5 and 100 Ohm. Up to 30 probe calibrations can be stored along with the calibration expiry date so the instrument can warn when the calibration time has been exceeded. Built in statistics calculation can show you both the measured and average values along with the standard deviation over previous measurements. The Isotech TTI-22 is ideal as a reference standard alongside liquid calibration baths, for the smallest uncertainty calibration with Dry Blocks or for demanding standalone measurement applications. Previously this level of performance was confined to specialist laboratories with expensive thermometry bridges; TTI-22 delivers 5 to 10 times the performance of comparably priced instruments. The TTI-22 uses the same patented measurement technique as the earlier TTI-2. Each measurement performs a zero point and gain correction. The switched polarity DC measuring current (0.4mA) eliminates thermal EMFs. Surface mount construction ensures long term reliability.


ВимірюванняГенерація (Імітація)


TTI-22

- -250°C to 962°C

- Quite simply the Isotech TTI-22 High Accuracy Thermometer sets new standards in the price to performance ratio for industrial and secondary resistance thermometry.

- Accuracy of 0.001°C and a resolution of 0.0001°C (0.00004 Ohms)

- A reference thermometer for your PRT or SPRT Standards

- For use in the lab or to achieve the highest accuracy in the field

Featured Products

PROGRAPH Measurement Analysis Software
Software Designed to be used in conjunction with the 8000 Precision Multimeter Series and 8500 Low Thermal Scanner, ProGraph provides an instant solution for graphing stability, temperature and many other parameters. ProGraph is a 'plug and...
Код: PROGRAPH
ACal (9530) Calibration Software
ACal (9530) Calibration Software
Additel ACal (9530) is a powerful software package designed for varying degrees of automation of calibrations and management of your laboratory. ACal combines pressure and temperature instrument calibration automation features with laborato...
Код: Acal
Oxygen Combustion Control Analyzer - Michell XZR500
Oxygen Combustion Control Analyzer - Michell XZR500
The XZR500 oxygen analyzer from Michell Instruments is designed to determine the excess air required for optimum combustion. It uses advanced Zirconium Oxide technology to measure levels of oxygen in harsh conditions such as boilers, incine...
Код: XZR500
Working Standard WS 2330 Series
Working Standard WS 2330 Series
The Working Standard WS 2330 is a three-phase precision reference meter for electrical power and energy measurement, dedicated to on-site meter testing. The device provides also function of local data exchange with smart meters (data readou...
Код: 3121
Standard Resistors
Standard Resistors
Eventually all resistance thermometry refers back to one or more fixed resistors. These are a key element in any laboratory which measures temperature. The resistors need to be very stable with time, temperature and transportation, and they...
Код:
Precision Electronically Compensated Voltage Transformer CMR-U
Other Features The Common Mode Rejecter (CMR) is an electronically compensated uncoupling unit for elimination of interaction of simultaneously tested electricity meters having interconnected current and voltage circuits (closed I-P links)....
Код: CMR-U
Explosion Proof Moisture Transmitter - Easidew PRO XP
Explosion Proof Moisture Transmitter - Easidew PRO XP
The Easidew PRO XP moisture transmitter is an explosion-proof dew-point transmitter for trace moisture measurements in gases or liquids in hazardous areas. It is certified by ATEX, CQPSUS, IECEx, and GOST for use in any North American, Euro...
Код: Easidew PRO XP
Gemini R Model 976
Gemini R Model 976
The Gemini R 550 Portable Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to 550°C. It is suitable for use as a primary radiation source for infrared thermometers. Labo...
Код: 976
IO620-PRV-PX/HX Pressure relief valve
IO620-PRV-PX/HX Pressure relief valve
Pressure relief valve When fitted to a PV62X pressure station a relief valve protects the PM620 pressure module and the device under test from overpressure...
Код: IO620-PRV-PX/HX
Medium Temperature Furnace
Medium Temperature Furnace
Whilst heat pipe furnaces offer the ideal environment to melt and freeze ITS-90 Fixed Points the temperature range is limited by fluid that flows inside the pipe. Three zone furnaces can offer wider operating ranges and still meet the requi...
Код:
TTI-10 High Accuracy Handheld Thermometer
TTI-10 High Accuracy Handheld Thermometer
TTI-10 brings laboratory level performance of up to 10mK (0.01°C) and resolution up to 0.001°C in a portable handheld instrument. Battery life is typically 20 hours from a 9V PP3 battery and a protective rubber boot offers protection in fie...
Код: I-10
Semi Standard Thermocouples
Semi Standard Thermocouples
These thermocouples are suitable for use as references in Isotech Dry Blocks and for use with temperature indicators. Details of our laboratory grade Standard Thermocouples with separate cold junctions can be found in our publication “Solut...
Код:
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
IO620-HOSE-H2 High pressure hydraulic hose
A high pressure hydraulic hose rated to 1,000 bar (15,000 psi) and terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. The hose is self sealing to avoid leakage...
Код: IO620-HOSE-H2
IO620-CASE-2 Carrying case
IO620-CASE-2 Carrying case
System carrying case Protective carrying case for system components including the DPI620G, MC620G, PM620 modules, test leads, hose and adaptors...
Код: IO620-CASE-2
PG9602/9607 Piston Gauge
PG9602/9607 Piston Gauge
The PG9607 is the next generation of absolute pressure piston gauge from Fluke Calibration. It supports the use of a 100 kg mass set to define gauge and absolute pressures from 11 to 500 kPa with a single piston-cylinder. The PG9602 is the ...
Код: PG9602/9607
HPPP480 Calibration system for gas meters with natural gas
HPPP480 Calibration system for gas meters with natural gas The calibration system serves as a standard for the calibration of gas meters of natural gas. The supply of natural gas occurs directly from a pipeline. The gas used for calibrat...
Код: HPPP480
Dew-Point Calibration System - Michell DCS
Dew-Point Calibration System - Michell DCS
The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a maximum of +20°C (+68°F). Through custo...
Код: DCS
8400B “Autosal” Laboratory Salinometer
8400B “Autosal” Laboratory Salinometer
The 8400B “Autosal” Laboratory Salinometer is the “Industry Standard” for salinity measurements. A very stable temperature control bath and heat exchanger maintain the sample at a precisely defined temperature during analysis, avoiding the ...
Код: 8400B
Quick Cal Low
Quick Cal Low
Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary. The Low Temperature Quick Cal covers the temperature range of -12°C to +140°C, making it ide...
Код: Quick Cal Low