2468A Pitot/Static Primary Standard

- Pressure range to 400 inHg

- Accuracy: Up to ±0.5 feet, 0.003 knots

- Working media: clean nitrogen/air

- Intended for calibration Ps, Pt & Qc 

- Automatic rotation of loads

- Mounted level and adjustable feet

Brief specifications

Pressure range from 0.4 to 103 inHg and from 3.4 to 400 inHg

Accuracy: Up to ±0.5 feet, 0.003 knots

High long-term stability up to 3 ppm per year

Working media: clean/dry nitrogen or air

Intended for absolute and gauge calibration for Ps, Pt & Qc ranges

Automatic rotation of loads

Mounted spirit level and adjustable feet

Gauge, absolute, vacuum (negative gauge) measurement modes

Non-magnetic materials to provide long-term stability

Monitoring of temperature, humidity, pressure and air density (option)

More details

The Model 2468 Pitot Static Primary Standard is specifically designed for calibrating today’s high performance flight line and Air Data Test Systems. With the new autofloat controller, operator intervention is reduced to simply applying the mass load indicated by WinPrompt® software. WinPrompt applies all required correction factors, real time, to insure attainment of the highest level of performance available in a gas piston gauge which is required to calibrate today’s RVSM compliant test sets. The Model 2468 is based on the popular Model 2465 Gas Piston Gauge which has a long history of serving national standards laboratories, commercial industry and government organizations as a primary pressure standard for over 50 years. Time-proven materials, hand craftsmanship, and a lineage of intercomparisons to national standards laboratories at the highest levels are coupled with new automated technology to make the Model 2468 Pitot Static Primary Standard the world’s choice for calibrating Air Data Test Systems.

Piston/cylinder assemblies

For calibrating most Pitot Static Test Sets, only the standard piston/cylinder supplied is required. The standard piston/cylinder generates pressures from 1.4 to 103 inHg in autofloat mode and from 0.4 to 103 inHg using a manual pressure adjuster. This provides an effective altitude range from -610 to 19,812 meters (-2,000 to 65,000 feet) feet in autofloat mode -610 to 27,432 meters (-2,000 to 90,000 feet) using a manual adjuster) and airspeeds over 1,000 knots. An optional piston/cylinder is available for generating pressures from 3.4 to 400 inHg allowing calibration of other pressure related devices, such as pressure transducers.

Both the standard and optional piston/ cylinder assemblies are manufactured from proven materials that have evidenced superior strength, durability, low distortion, low thermal coefficients and virtually undetectable hysteresis over the last several decades, and have an unparalleled record of long-term stability. Each piston/cylinder installs quickly into the pressure column without the need for special tools. Piston/cylinder assembly change-out can be completed in less than one minute.

Mass set

The Model 2468 is provided with a single mass set that is used with either the standard or optional piston/cylinder. Each mass is engraved with a unique sequence number and a common serial number. A storage case is supplied which allows storage of the mass set and one or both piston/cylinders. Each mass is machined to a nominal value and is made from nonmagnetic materials to provide long-term stability and eliminate sensitivity to magnetic fields. For ease of use, the entire mass set totals just 12 kilograms (26.40 pounds), with a maximum platter mass of 1 kilogram (2.2 pounds). A laboratory grade trim mass set is included to allow any pressure increment within the range and resolution of the piston/cylinder assembly.

Instrument base

The instrument base is designed with functionality, economy and space conservation in mind. All electronic components are housed away from the instrument base to eliminate errors caused by thermal effects and magnetic fields. The thermally isolated motor drive is connected to the cylinder—eliminating pressure fluctuations and maximizing productivity. A durable, acrylic bell jar is provided to allow absolute mode operation when calibrating altitude and other absolute reference devices. A KF16 fitting is provided to simplify installation and allow low reference pressures

Vacuum pumps

In order to operate over the entire altitude and airspeed range, two vacuum pumps are required. One pump is connected to the reference port of the Model 2468 using a KF16 connection. This allows the area inside the bell jar to be evacuated which is required for altitude calibrations (absolute mode). A second vacuum pump is connected to the autofloat controller which allows automatic control of pressures down to 1.4 inHg absolute. In order to generate positive pressures, a regulated gas supply (clean dry air, or nitrogen) must be supplied to the autofloat controller. Fluke Calibration can supply vacuum pumps which are rated to the appropriate vacuum capacity and include an auto-vent valve and backstream filter for contamination prevention along with a muffler for quiet operation.

Connecting lines and fittings

Fluke Calibration can provide an optional lines and fittings kit which includes all interconnecting tubing for pressure and vacuum supplies along with all required cables and adapters.

Manual configuration

Fluke Calibration also offers a manually operated pressure control system for setting the pressure and float position. This configuration can also be used with WinPrompt software and the Model 2456 Deadweight Gauge Monitor. The Model 2456 continuously monitors piston temperature, float position, and sink rate, and optionally air density and reference vacuum. WinPrompt calculates mass-to-pressure and pressure-to-mass values, and when used with the Model 2456, automatically reads and displays real-time piston gauge parameters. A separate brochure is available that covers the Model 2456 Deadweight Gauge Monitor.


ВимірюванняГенерація (Імітація)


2468A Pitot/Static Primary Standard

- Pressure range to 400 inHg

- Accuracy: Up to ±0.5 feet, 0.003 knots

- Working media: clean nitrogen/air

- Intended for calibration Ps, Pt & Qc 

- Automatic rotation of loads

- Mounted level and adjustable feet

Featured Products

Moisture in Liquid Analyzer - Michell Liquidew I.S.
Moisture in Liquid Analyzer - Michell Liquidew I.S.
Intrinsically safe moisture in liquids analyzer for fast, reliable on-line measurements. Continuous online measurement allows monitoring and control of processes to maximise efficiency for production and maintenance. Based on the Michell C...
Код: Liquidew I.S.
P5521, P5522 Liquid-to-Liquid Separators
P5521 and P5522 Liquid-toLiquid Separators These liquid-to-liquid separators connect directly to the test port of a hydraulic deadweight tester or comparison test pump. A flexible diaphragm separates the fluids, protecting the calibrator...
Код: P5521
2700G  Reference Pressure Gauge
2700G  Reference Pressure Gauge
The 2700G Reference Pressure Gauges provide best-in-class measurement performance in a rugged, easy-to-use, economical package. Improved measurement accuracy allows it to be used for a wide variety of applications. It is ideal for calibrati...
Код: 2700G
Gemini R Model 976
Gemini R Model 976
The Gemini R 550 Portable Blackbody Calibration Source allows for calibration of noncontact infrared thermometers over the temperature range 30°C to 550°C. It is suitable for use as a primary radiation source for infrared thermometers. Labo...
Код: 976
IO620-USB-PC USB cable
USB cable Connects the DPI620G or DPI620G-IS to a PC...
Код: IO620-USB-PC
6622T Temperature Bridge Series
6622T Temperature Bridge Series
The 6622T Temperature Bridge Series expands upon the success of 6622A Series Resistance Bridges by utilizing new design features to offer leading uncertainties and stabilities for Temperature Bridges. The 6622T Operating Range is from 0.1 Ω...
Код: 6622T
9340-4T Series of precision RTD Simulators and DC Resistance Standards
9340-4T Series of precision RTD Simulators and DC Resistance Standards
Guildline Instruments 9340-4T Series of precision RTD Simulators and DC Resistance Standards are a complete family of easy to use low to ultra-low, 4 Wire resistance standards offering the best combination of accuracy and resistance range t...
Код: 9340-4T
8500 Low Thermal 10 Channel Scanner low thermal scanner
8500 Low Thermal 10 Channel Scanner low thermal scanner
Automation of measurements using the 8500 Low Thermal Scanner allows a completely automated measurement system to be realised. Using the 8500 Scanner together with ProGraph software and the 8000 series multimeter provides a turnkey solution...
4.0000/5 1text_less_review
Код: 8500
Mercury Triple Point Cell
Mercury Triple Point Cell
The Isotech Mercury Cell Model is constructed in a rugged, sealed stainless steel enclosure allowing the triple point of -38.8344°C to be realized both easily and safely. Total Confidence The embodiment of the Mercury Triple Point Cell was ...
Код:
IO620-CHARGER External battery charging station
IO620-CHARGER External battery charging station
This external battery charging station allows a spare battery to be charged independently of the DPI620G for minimum instrument down time. Power is provided by the standard mains adaptor (P/N I0620-PSU). A complete charge cycle takes approx...
Код: IO620-CHARGER
Industrial Grade Chilled Mirror Hygrometer - Michell Optidew 401/501
Industrial Grade Chilled Mirror Hygrometer - Michell Optidew 401/501
The Optidew 401 and Optidew 501 are fast-responding chilled mirror hygrometers utilizing the latest developments in chilled mirror technology. Ideal for use in industrial humidity control and precision laboratory applications. Available in ...
Код: Optidew
2090 PROGRAMMABLE DECADE RESISTANCE BOX precision references and standards
Connect the 2090 via RS232 connection (USB to RS232 adapter available) to a computer to automate any task performed by a decade resistance box to automate calibration or ATE tasks. Providing a basic accuracy of up to 0.1% (0.01% accuracy op...
Код: 2090
9200B PORTABLE electrical tesr equipment calibrator
9200B PORTABLE electrical tesr equipment calibrator
The industry leading 3200B series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers. By using the 3200B series, calibration time can be drastically reduced, while superior accuracy me...
Код: 9200B
PG7202 High Pressure Gas/Hydraulic Piston Gauge
PG7202 High Pressure Gas/Hydraulic Piston Gauge
The piston gauge’s fundamental operating principle and excellent long term stability have made it an indispensable tool in high accuracy pressure metrology. As accuracy levels increase, quality assurance requirements intensify and automatio...
Код: PG7202
New Reference Standard
New Reference Standard
The Reference Standard RS 3330 is designed for the highest possible precision meter for quantities related to electrical power and energy measurements. The Reference Standard is designed to meet all requirements put on a reference standard ...
Код: New Reference Standard
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
Heavy Duty Transmitter Temperature and Humidity - Rotronic HF73A
The HF73A transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %rh and -100 to 150 °C (-148 to 302 °F). The probe of the HF73A can survive exposure to temperature...
Код: HF73A
Adapter Sets Fluke
Fluke P5540 Metric Adapter Set: Includes adapters: M14x1.5, M20x1.5, 1/8" BSP, and 1/4" BSP female. Designed for use with Fluke P5500 series hydraulic and pneumatic comparison test pumps, excluding P5514B. Fluke P5541 BSP Adapter Set: ...
Код: Adapter Sets P554x
3350A precision multiproduct calibrator
3350A precision multiproduct calibrator
The 33XXA Series multiproduct calibrators are modular versions of the class leading 3000A Series Calibrators. Designed to reduce cost, the 33XXA Series feature 0 - 20V DC output as standard with a wide range of options including 20V - 1000V...
3.7500/5 8text_lot_review
Код: 3350A
IO620-HOSE-H2-IS High pressure hydraulic hose in hazardous area use
A high pressure hydraulic hose rated to 1,000 bar (15,000 psi) and terminated with quick fit connectors compatible with the test point adaptors supplied with the PV62XG, MC620G and the adaptor sets. The hose is self sealing to avoid leakage...
Код: IO620-HOSE-H2-IS
IO620-BLANK Blanking plug
IO620-BLANK Blanking plug
Blanking plug Allows the PV621G and 622G to be used as pressure generators independently of the DPI620G and PM620 by blanking the PV62XG pressure module port. Not required for the PV623G as the port is self-sealing...
Код: IO620-BLANK