Dual and Heat Pipe Furnaces

- 125°C to 1090°C

- Isotech metrology furnaces have more than 35 years of proven use and are widely used by the worlds’ leading NMIs. Our controllers offer extra resolution and allow adjustment to 0.1°C right up to 1090°C. The furnaces have been updated with additional features to make operation simpler and safer.

- Essentially Gradient Free

- Heat pipe Operation from Indium to Copper

- Simple Use - no zone offsets to adjust

Brief specifications


More details

Heat Pipe Furnaces Isotech metrology furnaces have more than 35 years of proven use and are widely used by the worlds’ leading NMIs. For the optimal use of fixed point cells the temperature uniformity should be less than 10mK over the length of the fixed point sample CCT/2000-13, “Optimal Realization of the Defining Points of the ITS-90…” Isotech heat pipe furnaces offer essentially gradient free operation; heat pipes provide the ideal conditions for the creation and maintenance of ITS-90 fixed point cells. Unlike some other companies Isotech can provide heat pipe furnaces to suit Indium, Tin, Zinc, Aluminum, Silver and Copper fixed points. Plateau length is determined by the difference in temperature between the heat pipe and cell – this can be adjusted to give a plateau of any length of up to tens of hours. Our controllers offer extra resolution and allow adjustment to 0.1°C right up to 1090°C. The Potassium and Sodium models have a cooling coil in the lid with connections to circulate tap water to keep the furnace lid cool protecting the SPRT and reducing heat load into the lab. A pre warming tube with a temperature approximately equal to that of the heat pipe made of a unique and gas-tight material, is provided to heat the SPRT prior to it being placed in a cell. The furnaces feature an adjustable independent and adjustable over temperature device to protect expensive cells and SPRTs as well as a second internal over temperature safety device. Dual Furnaces In addition to the heat pipe furnaces described the Dual Furnaces incorporate a second furnace which, because of its unique design, will safely (and without contamination) pre and post-condition the thermometers. There is also a separate storage enclosure for up to four thermometers with adequate support for the thermometer head. With the Dual Furnace the thermometers are removed from their storage enclosure and placed in the pre-conditioning furnace. The furnace is slowly heated to the Cell temperature. The thermometers are protected from contamination by a slow air flux around them. One by one the thermometers are transferred into the cell for 20 to 30 minutes for calibration and thence back to the conditioning furnace. When all the thermometers have been calibrated, the conditioning furnace is slowly cooled back to 400°C whence the thermometers can safely be removed into room temperature. New Features From our own ongoing experience and customer feedback we have updated the Isotech Furnace Range to deliver the same proven performance and advanced features but with a number of convenience upgrades to make your life easier. The controllers have now been relocated to the top for easier operation, we now include an SPRT Stand and Cable Tidies to keep your standards safe and Accessory Pods to keep the furnace tops free from clutter. Our furnaces are programmable to automatically melt and freeze cells and feature both USB and Ethernet interfaces with bright crystal clear displays.


ВимірюванняГенерація (Імітація)


Dual and Heat Pipe Furnaces

- 125°C to 1090°C

- Isotech metrology furnaces have more than 35 years of proven use and are widely used by the worlds’ leading NMIs. Our controllers offer extra resolution and allow adjustment to 0.1°C right up to 1090°C. The furnaces have been updated with additional features to make operation simpler and safer.

- Essentially Gradient Free

- Heat pipe Operation from Indium to Copper

- Simple Use - no zone offsets to adjust

Featured Products

Ice mantle maker for water triple point cells
Ice mantle maker for water triple point cells
Are you fed up with cold wet hands, and hours of frustration when you produce an ice mantle in your Triple Point Cell? Change your life and try the Isotech Ice Mantle Maker. It works by using a specially designed anti-gravity heat pipe. The...
Код: Ice mantle
Filters and Filter Carriers for Rotronic HC2A Humidity Probes
Filters and Filter Carriers for Rotronic HC2A Humidity Probes
Filter carriers protect the humidity and temperature sensors and probes against mechanical damage. Filters act as a protective barrier against contaminants/pollutants that can influence the sensor. When choosing the correct combination of f...
Код: HC2A
AII GPR-1800 PPM Oxygen Analyzer
AII GPR-1800 PPM Oxygen Analyzer
The GPR-1800 series of intrinsically safe trace oxygen analyzers are designed for use in demanding process environments where the low detection limit down the AII’s industrial oxygen sensors can be well utilized. Typical for Analytical Indu...
Код: GPR-1800
7252/7252i  Pressure Controllers
7252/7252i  Pressure Controllers
Adding to the flexibility of the Series 7252, two performance models are available: the Model 7252i that offers percent of reading performance further extending the capabilities of a single calibrator, or the Model 7252, that provides perce...
Код: Fluke 7252
3000AC voltage reference precision references and standards
The 3000AC provides laboratories with a fully traceable AC voltage source with accuracies in the order of 10ppm that can easily be verified with a DC voltage multimeter with accuracies in the 4ppm to 10ppm region. Using the latest in DAC te...
5.0000/5 2text_more_review
Код: 3000AC
Hydra Model 798M
Hydra Model 798M
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798M
Cyclops Model 878
Cyclops Model 878
The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for use as a radiation source for infrared thermometers. The inner sphere has a nominal diamete...
4.0000/5 2text_more_review
Код: 879
Adapters
Adapters
A complete list of possible adapters is indicated in the specifications...
Код: Адаптер
8500 Low Thermal 10 Channel Scanner low thermal scanner
8500 Low Thermal 10 Channel Scanner low thermal scanner
Automation of measurements using the 8500 Low Thermal Scanner allows a completely automated measurement system to be realised. Using the 8500 Scanner together with ProGraph software and the 8000 series multimeter provides a turnkey solution...
4.0000/5 1text_less_review
Код: 8500
AII GPR-1900 Oxygen Analyzer With Remote Sensor
A panel mounted oxygen analyser with a remote sensor allows flexibility of installation. The GPR-1900 gas analyzer is suitable for trace oxygen measurements as low as 0-10 ppm; the GPR-2900 measures O2 up to 100%. The remote sensor block al...
Код: GPR-1900
6640T SERIES OF TEMPERATURE BRIDGES
6640T SERIES OF TEMPERATURE BRIDGES
GUILDLINE’S NEW 6640T SERIES OF TEMPERATURE BRIDGES are redesigned to provide better uncertainties, faster measurement rates and more operational capability. PRODUCT FEATURES Best Accuracy: ± 0.015 ppm with 1 mA of Current Linearity: < ± 0....
Код: 6640T
Hydra Model 798L
Hydra Model 798L
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798L
Dew-Point Hygrometer - Michell Easidew Online
Dew-Point Hygrometer - Michell Easidew Online
Easy to install and maintain, the Easidew Online Hygrometer measures and displays dew point and moisture content for use in a wide range of moisture applications. The Easidew Online display provides analog, digital, and dual relay alarm out...
Код: Easidew Online
ISOTowers
ISOTowers
The most accurately defined temperatures are those defining points (fixed points) of ITS-90. The leading Primary Laboratories use large fixed point cells in deep calibration furnaces that utilise heat pipes to eliminate temperature gradient...
Код: ISOTowers
Flexible Current Probe SymmProFlex FCP 3x21
Precision Flexible AC Current Probes SymmProFlex® FCP 3121 and FCP 3321 are current probes based on Rogowski principle designed to measure alternating current up to 3000 A, 6000 A, 12000 A or more. Current Probes SymmProFlex® FCP 3121 (sing...
Код: SymmProFlex
Additel 282 Dual-Channel Reference Thermometer Readout
Additel 282 Dual-Channel Reference Thermometer Readout
Additel’s 282 Reference Thermometer Readout delivers the best possible accuracies and features in the palm of your hand With accuracy capabilities on par with laboratory grade thermometers, the ADT282 is capable of handling even your most c...
Код: ADT282
9334A SERIES of Resistance Standards
9334A SERIES of Resistance Standards
GUILDLINE INSTRUMENTS 9334A SERIES of Resistance Standards are designed as very stable laboratory standards for high accuracy resistance calibration in air, without the need for a temperature controlled bath. PRODUCT FEATURES 12 Month Stabi...
Код: 9334A
ADTS554F  Air data test system
ADTS554F  Air data test system
The ADTS554F air data test set is a portable four-channel flightline pitot static tester. In three-channel mode, it provides pitot static air data validation, leak testing, fault-finding and avionics instrumentation testing for any aircraft...
Код: ADTS554F
IO620-CASE-1 Carrying case
IO620-CASE-1 Carrying case
Carrying case Protective carrying case with belt loop, shoulder strap and large detachable pocket for test leads and accessories...
Код: IO620-CASE-1
P5544 Two Gauge Stand
This adapter mounts directly to the test port of the calibrator and allows for the calibration of two instruments at the same time, or the connection of a reference test instrument. Maximum working pressure is 10,000 psi (700 bar)...
Код: P5544
Спасибо!