A wall mounted oxygen analyzer in a NEMA enclosure, suitable for indoor or outdoor. This single channel oxygen monitor is supplied with a stainless steel O2 sensor housing for trace oxygen gas analysis in safe as well as hazardous areas where ATEX approval is needed. The low detection limit of 0.05ppm allows a minimum oxygen measurement range of 0 to 10 ppm O2. Ideal for clean gas applications and when used with the XLT oxygen sensor type it allows measurement in pure carbon dioxide. The Analytical Industries long-life oxygen sensors are maintenance-free sealed electrochemical cells that don’t need top up of electrolyte and can be exchanged in few minutes.
Документация
-
GPR-1500 Data Sheet ENG (246.39KB)
-
GPR-1500 GB Data Sheet ENG (248.39KB)
-
GPR-1500 Oxygen Data Sheet ENG (222.7KB)
-
GPR-1500 ATEX User Manual ENG (1.13MB)
-
GPR-1500 DK User Manual ENG (1.19MB)
-
GPR-1500 D User Manual ENG (1.65MB)
-
GPR-1500 A User Manual ENG (652.42KB)
-
GPR-1500 AIS User Manual ENG (1.39MB)
-
GPR-1500 AIS-LD User Manual ENG (1.41MB)
-
GPR-1500 DA User Manual ENG (951.23KB)
-
GPR-1500 GB User Manual ENG (934.9KB)
-
GPR-1500 IS-LD User Manual ENG (1.26MB)
-
GPR-1500 N User Manual ENG (1.16MB)
AII GPR-1500 PPM Oxygen Analyzer/ Transmitter
-Accuracy: < 2% of FS range under constant conditions
Analysis: 0-10, 0-100, 0-1000 PPM, 0-1%, 0-25% (CAL) FS Auto-ranging or manual lock on a single range
Application: Oxygen analysis in inert, hydrocarbon, helium, hydrogen, mixed and acid (CO2) or atmospheres in glove boxes
Area Classification: General purpose or Certified for use in hazardous areas
Enclosure: Painted aluminum or NEMA Type 3R for rain in outdoor applications (UL) NEMA 4X (ATEX)
Flow: Not flow sensitive; 1-2 SCFH flow rate recommended
Pressure: Atmospheric; Flowing system: inlet - regulate to 5-30 psig, vent - atmospheric or return controlled atmosphere
Power: 18-24 VDC two wire loop; 12-28 VDC (cUL and ATEX Certified) 110-220 VAC (ATEX Certified)
Sample System: Glove box Sample Calibration Module (pictured right) or Sample flow meter; options available, see other side; Unique liquid drain sensor manifold, flow indicator
Sensor Model: GPR-12-333-M for non-acid (CO2) gas streams XLT-12-333-M for gases containing > 0.5% CO2
Operating Range: 5ºC to 45ºC (GPR sensor), -10ºC to 45ºC (XLT sensor); -10ºC to 45ºC (GPR sensor); -18ºC to 45ºC (XLT)