Dew-Point Calibration System - Michell DCS

- All-in-One Configurable Calibration Station

- Features

-

- Complete dew-point calibration solution with optional compressor, dryer, dew-point generator, reference instrument and optional manifold

- Generated output responds quickly to a change of set point

- Stable humidity generation

- Simple operation through manual flow mixing or push-button switching of set points

- Remote control via RS232 comms (dependant on model)

Brief specifications


More details

The DCS system is a complete rack-mounted calibration station capable of producing a flow of air (or nitrogen) at a pre-specified range of dew-point temperatures from a minimum of -100°C (-148°F) to a maximum of +20°C (+68°F). Through customization the DCS system can be PC controlled for automated calibration sequences or manually operated at pre-determined dew-point set points.

When ordering this system, simply specify the required operating range, and Michell Instruments will determine the most economical way to construct your calibration system.


ВимірюванняГенерація (Імітація)


Документация

Dew-Point Calibration System - Michell DCS

- All-in-One Configurable Calibration Station

- Features

-

- Complete dew-point calibration solution with optional compressor, dryer, dew-point generator, reference instrument and optional manifold

- Generated output responds quickly to a change of set point

- Stable humidity generation

- Simple operation through manual flow mixing or push-button switching of set points

- Remote control via RS232 comms (dependant on model)

Featured Products

P5523 Liquid-to-Gas Media Separator
For high pressure pneumatic calibrations this unit interfaces with hydraulic deadweight testers providing a rateless liquid-to gas separation. Driven by a pneumatic pressure source (nitrogen bottle) and controlled by needle valves, high pre...
Код: P5523
ACal (9530) Calibration Software
ACal (9530) Calibration Software
Additel ACal (9530) is a powerful software package designed for varying degrees of automation of calibrations and management of your laboratory. ACal combines pressure and temperature instrument calibration automation features with laborato...
Код: Acal
Electricity Meter Test Equipment ELMA 8x01
The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals. The available power and the max...
Код: ELMA 8x01
7252/7252i  Pressure Controllers
7252/7252i  Pressure Controllers
Adding to the flexibility of the Series 7252, two performance models are available: the Model 7252i that offers percent of reading performance further extending the capabilities of a single calibrator, or the Model 7252, that provides perce...
Код: Fluke 7252
3000HR precision resistance standard precision references and standards
3000HR precision resistance standard precision references and standards
The 3000HR provides a traceable source for high voltage resistance, consisting of a buildup box of 1 GOhm and 10 Gohm resistors, allowing a buildup to 100 Gohm. High value resistance standards are required by many laboratories for calibrati...
5.0000/5 2text_more_review
Код: 3000HR
AC Shunt Accessories
Complete Selection of Measurement Accessories for the 7340 and 7350 Series of AC Shunts. AVAILABLE PRODUCTS AND FEATURES Forced Air Convection Unit provides excellent heat dissipation and a more stable output AC Buffer Amplifier for low cur...
Код: AC
AII GPR-2800 Process Oxygen Analyzers
AII GPR-2800 Process Oxygen Analyzers
Accuracy < 2% of selected range at constant conditions Four measurement ranges 0-1%, 0-5%, 0-10% & 0-25% O2 Sensitivity (LDL) 0.005% (50 ppm) O2 UL or ATEX certified for use in hazardous areas Low maintenance with an average sensor life...
Код: GPR-2800
7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER
7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER
GUILDLINE INSTRUMENTS 7810 WIDEBAND TRANSCONDUCTANCE AMPLIFIER is the latest innovation for High Current, Wide Bandwidth AC Outputs. PRODUCT FEATURES 50 A and 100 A Models Calibrated Frequency Range (DC to 100 kHz) Uncalibrated 100 kHz to 2...
Код: 7810
DPI104 Digital Pressure Gauge
DPI104 Digital Pressure Gauge
The DPI104 is a microprocessor-controlled digital pressure gauge that combines precision and functionality in a compact, robust, and simple-to-use package. The DPI 04 matches advanced silicon sensor technology with several convenient design...
Код: DPI104
Semi Standard Thermocouples
Semi Standard Thermocouples
These thermocouples are suitable for use as references in Isotech Dry Blocks and for use with temperature indicators. Details of our laboratory grade Standard Thermocouples with separate cold junctions can be found in our publication “Solut...
Код:
3000RS precision resistance standard precision references and standards
3000RS precision resistance standard precision references and standards
The 3000RS is a modern precision resistance standard offering annual stabilities of better than 5ppm without the requirement for an oil bath, with temperature co-efficients as low as 0.1ppm/°C Using ultra-high precision, 4 wire hermetically...
Код: 3000RS
Orion Model 796H
Orion Model 796H
The Isotech Hydra range of calibration baths have proved very successful since their introduction in 2003. The Orion range has been introduced to fit alongside the Hydra models. The Orion calibration baths offer deeper calibration volumes t...
Код: 796H
786 Model
786 Model
Operate confidently in cold environments, even as low as -29°C. The ruggedly designed Model 786 takes laboratory level performance into the harshest of environments. Unlike other calibrators that cannot be used in the extreme cold, the 7...
Код: 786
AC/DC shunts precision references and standards
AC/DC shunts precision references and standards
Transmille offer a set of current shunts enabling measurement of current from 1mA through to 100A. Each shunt develops 0.7V at nominal full scale, enabling a wide range of multimeters to be used without loss of resolution due to changing ra...
Код: AC/DC
Quick Cal High
Quick Cal High
Isotech’s Quick Cal range of testers are ideally suited to the less exacting applications where our larger, better specified baths are unnecessary. The Low Temperature Quick Cal covers the temperature range of -12°C to +140°C, making it ide...
Код: Quick Cal High
Hydra Model 798M
Hydra Model 798M
Precision calibration of thermometers calls for the use of stirred liquid calibration baths. The Hydra models set new standards in terms of price to performance ratio. Now Calibration Engineers and Metrologists can choose from a range of ba...
Код: 798M
6634A SERIES
6634A SERIES
GUILDLINE INSTRUMENTS 6634A SERIES is a modular series of Resistance Standards that can be rack mountable or simply set on a bench. The 6634A Series provides a set of up to 10 precision resistance standards enclosed in a temperature control...
Код: 6634A
Additel 875 Dry Well Calibrator
Additel 875 Dry Well Calibrator
If you are serious about portable temperature calibration tools, then you know a good dry well calibrator is more than just a stable heat source. The Additel 875 Series Dry Well Calibrators combine excellent performance in stability, radial...
Код: ADT875-350
PEGASUS-T
PEGASUS-T
New Solution…to Calibrate Short Sensors at High Temperatures The Pegasus range offers extreme high temperature calibration in an easy to use portable package – ideal for the calibration of high temperature thermocouples. It has been designe...
Код: PEGASUS-T
3000CS precision curent shunts precision references and standards
The 3000CS provides a precision set of current shunts for current ranges from 10mA through to 10A to provide additional ranges for multimeters that either lack sufficient accuracy at required currents, or lack the required current ranges en...
4.5000/5 14text_more_review
Код: 3000CS